| High Voltage Shut-off Procedures |
|
|
| 1. | Turn the ignition switch OFF and disconnect the auxiliary (-) battery negative (-) terminal. |
| 2. | Remove the safety plug cover (A).
|
| 3. | Unfasten the hook (A) and then remove the safety plug (C) by pulling the lever (B) to the direction of arrow.
|
| 4. | Wait for more than 5 minutes so that the capacitor in the high voltage system can be fully discharged. |
| 5. | Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Safety PrecautionPrecautions To Take Before Servicing High Voltage System • Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.
SpecificationsFuel Delivery System Items Specification Fuel TankCapacity45â„“ lit. (11.8 U.
Replacement1.Remove the battery (-) terminal.2.Remove the engine room under cover.(Refer to Engine Mechanical System - "Engine Room Under Cover")3.Remove the heater hose (A) and AEWP hose (B).4.Disconnect the lock pin to remove the heater hose pump connector (A).
C