| High Voltage Shut-off Procedures |
|
|
| 1. | Turn the ignition switch OFF and disconnect the auxiliary (-) battery negative (-) terminal. |
| 2. | Remove the safety plug cover (A).
|
| 3. | Unfasten the hook (A) and then remove the safety plug (C) by pulling the lever (B) to the direction of arrow.
|
| 4. | Wait for more than 5 minutes so that the capacitor in the high voltage system can be fully discharged. |
| 5. | Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Safety PrecautionPrecautions To Take Before Servicing High Voltage System • Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.
DescriptionTransmits or blocks the driving power of the engine when switching between the EV and HEV modes.
Diagnosis With GDS1.The heating, ventilation and air conditioning can be quickly diagnosed failed parts with vehicle diagnostic system (GDS).※ The diagnostic system (GDS) provides the following information.(1) Self diagnosis : Checking the failure code (DTC) and display.
C