| High Voltage Shut-off Procedures |
|
|
| 1. | Turn the ignition switch OFF and disconnect the auxiliary (-) battery negative (-) terminal. |
| 2. | Remove the safety plug cover (A).
|
| 3. | Unfasten the hook (A) and then remove the safety plug (C) by pulling the lever (B) to the direction of arrow.
|
| 4. | Wait for more than 5 minutes so that the capacitor in the high voltage system can be fully discharged. |
| 5. | Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Safety PrecautionPrecautions To Take Before Servicing High Voltage System • Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.
SpecificationsHybrid motor Drive motor Category Drive motor TypePermanent magnet synchronous motor(Interior Permanent Magnet Synchronous Motor)Maximum output32kW (driving), 35kW (regeneration)Maximum torque170 N.
Replacement1.Disconnect the negative (-) battery terminal. 2.Remove the heater and blower assembly.(Refer to Heater - "Heater Unit") 3.Loosen the mounting screws and remove the driver's temperature control actuator (A).4.Remove the heater core cover (A) after loosening the mounting screws.
DescriptionThe auto defogging sensor is installed on front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives a signal from the sensor and restrains moisture and eliminates defog by the intake actuator, A/C, auto defogging actuator, blower motor rpm and mod