| Description |
Component Location1. HPCU (Hybrid Power Control Unit)2. HCU (Hybrid Control Unit)3. Brake Switch4. DC Fuse • HPCU includes the HCU (Hybrid Control Unit), Inverters (for Drive Motor, HSG and Electric A/C Compressor), MCU (Motor Control Unit) and LDC (Low DC / DC Converter).
Components1. Hybrid Control Unit (HCU)2. Inverter3. Low DC/DC Converter (LDC)4. Connector (↔ High Voltage Battery)5. Connector (↔ Motor)6. Connector (↔ HSG)7.
Inspection1.Turn the ignition switch OFF. 2.Disconnect the auto defogging connector. 3.Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.
Replacement When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage.1.Disconnect the negative (-) battery terminal.2.Recover the refrigerant with a recovery / recycling / charging station.