| Specification |
|
item
|
Specification
| ||
| Compressor | Type | HES20 (Electric Scroll) | |
| Communication type | CAN communication | ||
| Oil type & Capacity | POE Oil, 130 ± 10cc (4.58 ± 0.35oz.) | ||
| Motor type | BLDC | ||
| Rated voltage | 240V | ||
| Operation voltage | 160 - 275V | ||
| Expansion valve | Type | Block type | |
| Refrigerant | Type | For Europe (Regulated area) | Except Europe |
| R - 1234yf | R - 134a | ||
| Capacity | 600 ± 25 g (21.2 ± 0.88 oz.) | ||
|
Item
|
Specification
| |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco pan |
| Speed step | Auto + 8 speed (Automatic) | |
| Air filter | Type | Particle filter |
|
Item
|
Specification
| |||
| Heater | Type | Fin & Tube type | ||
| Type | Tube - Fin 1Way | |||
| Mode operating method | Actuator | |||
| Temperature operating method | Actuator | |||
| Evaporator | Temperature control type | Evaporator temperature sensor | ||
| Blower singular | A/C Output OFF Temperature | A/C Output ON Temperature | ||
| Manual control | 1 - 2 speed | 1.5°C (34.7°F) | 3.0°C (37.4°F) | |
| 3 - 4 speed | 0.6°C (33.1°F) | 2.1°C (35.8°F) | ||
| Dual control | 1 - 4 speed | 1.5°C (34.7°F) | 3.0°C (37.4°F) | |
| 5 - 6 speed | 1.0°C (33.8°F) | 2.5°C (36.5°F) | ||
| 7 - 8 speed | 0.6°C (33.1°F) | 2.1°C (35.8°F) | ||
| Manufacturer | HVCC (Halla Visteon Climate Control) | |||
| Tightening Torques |
|
Items
|
N.m
|
kgf.m
|
lb-ft
|
| Compressor | 20.0 - 32.95 | 2.04 - 3.36 | 14.75 - 24.30 |
| Condenser - Discharge hose | 8.8 - 13.7 | 0.9 - 1.4 | 6.5 - 10.1 |
| Condenser - Liquid tube | |||
| Compressor - Discharge hose | 7.8 - 11.8 | 0.8 - 1.2 | 5.8 - 8.7 |
| Compressor - Suction hose | |||
| Expansion valve - Evaporator | 8.8 - 13.7 | 0.9 - 1.4 | 6.5 - 10.1 |
High Voltage Shut-off Procedures • Be sure to read and follow the "General Safety Information and Caution" before doing any work related with the high voltage system.
TroubleshootingProblem Symptoms TableBefore replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Inspection1.Turn the ignition switch ON.2.Connect the GDS.3.Emit intensive light toward the photo sensor using a lamp, and check the output voltage change.4.The voltage will rise with higher intensive light and reduce with lower intensive light.1. Auto light signal2.
Replacement1.Disconnect the negative (-) battery terminal. 2.Remove the heater and blower assembly.(Refer to Heater - "Heater Unit") 3.Loosen the mounting screws and remove the driver's temperature control actuator (A).4.Remove the heater core cover (A) after loosening the mounting screws.