Symptom
|
Suspected Area
|
| No blower operation | Blower fuse |
| Blower relay | |
| Blower motor | |
| Power mosfet | |
| Blower speed control switch | |
| Wire harness | |
| No air temperature control | Engine coolant capacity |
| Heater control assembly | |
| No compressor operation | Refrigerant capacity |
| A/C fuse | |
| Compressor | |
| A/C pressure transducer | |
| A/C switch | |
| Evaporator temperature sensor | |
| Wire harness | |
| Vented air not cold | Refrigerant capacity |
| Refrigerant pressure | |
| Drive belt | |
| Compressor | |
| A/C pressure transducer | |
| Evaporator temperature sensor | |
| A/C switch | |
| Heater control assembly | |
| Wire harness | |
| Insufficient cooling | Refrigerant capacity |
| Drive belt | |
| Compressor | |
| Condenser | |
| Expansion valve | |
| Evaporator | |
| Refrigerant lines | |
| A/C pressure transducer | |
| Heater control assembly | |
| No engine idle-up when A/C switch ON | Engine ECM |
| Wire harness | |
| No air inlet control | Heater control assembly |
| No mode control | Heater control assembly |
| Mode actuator | |
| No cooling fan operation | Cooling fan fuse |
| Fan motor | |
| Engine ECM | |
| Wire harness |
SpecificationAir Conditioner item Specification CompressorTypeHES20 (Electric Scroll)Communication typeCAN communicationOil type & CapacityPOE Oil, 130 ± 10cc (4.
DescriptionThe ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.The sensor output will be used for discharge temperature control, temperature regulation door contrl, blower m
Removal • Put on gloves to prevent hand injuries. • When removing with a flat-tip screwdriver or remover, wrap protective tape around the tools to prevent damage to components.