| Troubleshooting |
| Problem Symptoms Table |
|
Symptom
|
Suspected Area
|
| No blower operation | Blower fuse |
| Blower relay | |
| Blower motor | |
| Power mosfet | |
| Blower speed control switch | |
| Wire harness | |
| No air temperature control | Engine coolant capacity |
| Heater control assembly | |
| No compressor operation | Refrigerant capacity |
| A/C fuse | |
| Compressor | |
| A/C pressure transducer | |
| A/C switch | |
| Evaporator temperature sensor | |
| Wire harness | |
| Vented air not cold | Refrigerant capacity |
| Refrigerant pressure | |
| Drive belt | |
| Compressor | |
| A/C pressure transducer | |
| Evaporator temperature sensor | |
| A/C switch | |
| Heater control assembly | |
| Wire harness | |
| Insufficient cooling | Refrigerant capacity |
| Drive belt | |
| Compressor | |
| Condenser | |
| Expansion valve | |
| Evaporator | |
| Refrigerant lines | |
| A/C pressure transducer | |
| Heater control assembly | |
| No engine idle-up when A/C switch ON | Engine ECM |
| Wire harness | |
| No air inlet control | Heater control assembly |
| No mode control | Heater control assembly |
| Mode actuator | |
| No cooling fan operation | Cooling fan fuse |
| Fan motor | |
| Engine ECM | |
| Wire harness |
SpecificationAir Conditioner item Specification CompressorTypeHES20 (Electric Scroll)Communication typeCAN communicationOil type & CapacityPOE Oil, 130 ± 10cc (4.
Inspection • Before measuring the pressure of the refriferant line, check whether the refrigerant amount is charged in accordance with the specified charging amount.(Refer to Heating, Ventilation, Air Conditioning - "Specifications")1.
Replacement1.Remove the battery (-) terminal.2.Remove the engine room under cover.(Refer to Engine Mechanical System - "Engine Room Under Cover")3.Remove the heater hose (A) and AEWP hose (B).4.Disconnect the lock pin to remove the heater hose pump connector (A).