| Components Location |

| 1. Electric A/C Compressor |
| Components |

| 1. Electric A/C Compressor inverter assembly 2. Gasket | 3. Electric A/C Compressor body assembly |
DescriptionCompare to the belt-driven A/C compressor, the electric A/C compressor has several advantages. It can contribute to the improvement of EV fuel efficiency and it is possible to running air conditioner after engine stop during EV mode.
Connector ConfigurationsTerminal Function Connector Pin No. Function A112V Power Ground2Climate CAN Low3Interlock (-)412V Power5Climate CAN High6Interlock (+)B1High Voltage Power2High Voltage Ground3Compressor Interlock (-)4Compressor Interlock (+)
DescriptionThe ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.The sensor output will be used for discharge temperature control, temperature regulation door contrl, blower m
DescriptionThe temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch. Then the temperature will be regulated by the hot/cold air ratio decided by the position of the temper