| Operation Principle |

Inspection1. After disconnecting the vapor hose from the PCV valve, remove the PCV valve. 2. Reconnect the PCV valve to the vapor hose.3. Run the engine at idle, then put a finger over the open end of the PCV valve and make sure that intake manifold vacuum can be felt.
Removal1. Disconnect the vapor hose (A).2. Remove the PCV valve (B).Inspection1.Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.
Diagnosis With GDS1.The heating, ventilation and air conditioning can be quickly diagnosed failed parts with vehicle diagnostic system (GDS).※ The diagnostic system (GDS) provides the following information.(1) Self diagnosis : Checking the failure code (DTC) and display.