| Circuit Diagram |

Specification Item Value Rated voltage (V)400 (DC)Rated current (A)125 (DC)
Removal • Be sure to read and follow the "General Safety Information and Caution" before doing any work related with the high voltage system.
Inspection1.Connect the battery voltage and check the blower motor rotation.2.If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.3.Replace the blower motor if it is proved that there is a problem with it.
Inspection1.Turn the ignition switch OFF.2.Disconnect the intake actuator connector.3.Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.Verify that the intake actuator operates to the recirculation position when connected in reverse.