Hyundai Ioniq (AE): High Voltage Battery Control System / Pre Charge Relay. Specifications

Specification
Item
Specification
Contact
Rated Voltage (V)
450
Rated Current (A)
20
Coil
Operating Voltage (V)
12
Resistance (Ω)
40.0 - 110.0
[20°C (68°F)]

    DescriptionThe Power Relay Assembly (PRA) consists of the positive and negative main relays, pre-charge relay, pre-charge resistor and battery current sensor.

    Circuit Diagram

    Other information:

    Hyundai Ioniq (AE) 2017-2022 Service & Repair Manual: Evaporator Temperature Sensor. Repair procedures

    Inspection1.Turn the ignition switch OFF.2.Disconnect the evaporator temperature sensor connector.3.Measure the resistance between terminal "+" and "-" of the evaporator temperature sensor.Specification Evaporator core temperature [°C (°F)] Resistance [KΩ]

    Hyundai Ioniq (AE) 2017-2022 Service & Repair Manual: Blower Motor. Repair procedures

    Inspection1.Connect the battery voltage and check the blower motor rotation.2.If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.3.Replace the blower motor if it is proved that there is a problem with it.

    Categories

     