| Specification |
|
Item
|
Specification
|
| Input Voltage (V) | 200 - 310 |
| Output Voltage (V) | 12.8 - 14.7 |
| Rated Power (kW) | 1.8 |
| Cooling Method | Water-cooled |
DescriptionThe Low Voltage DC/DC is integrated into the HPCU. It charges the auxiliary battery as a substitute for generator by converting the high voltage (DC 270V) from the high voltage battery into low voltage (DC 12V).
Component Location1. Low Voltage DC/DC Converter (LDC)2. Power Outlet Terminal (DC 12V)3. Ground Terminal
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.
Diagnosis with GDS1.REAR CORENER RADAR system defects can be quickly diagnosed with the GDS. GDS operates actuator quickly to monitor, input/output value and self diagnosis.2.Connect the cable of GDS to the data link connector in driver side crash pad lower panel, turn the power on GDS.