| Specification |
|
Item
|
Specification
|
| Coil Resistance (Ω) | 2.37 - 2.7 |
|
Item
|
Specification
|
| Opened Voltage (V) | 0.7 - 1.3 |
| Closed Voltage (V) | 3.9 - 4.5 |
DescriptionThe Electric EGR Control Valve is installed in between the EGR cooler and the exhaust line and is a solenoid valve. This valve controls EGR (Exhaust Gas Recirculation) amount by the ECM's duty control signal depending on engine load and the need of intake air.
Signal WaveformFig.1) Duty control [EEGR Motor (-)] at deceleration or idleFig.2) Duty control [EEGR Motor (+)] at acceleration
DescriptionThe PTC (Positive Temperature Coefficient) heater is installed at the exit or the backside of the heater core.The PTC heater is an electric heater using a PTC element as an auxiliary heating device that supplements deficiency of interior heat source in highly effective hybrid engine.
Safety PrecautionPrecautions To Take Before Servicing High Voltage System • Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.