Hyundai Ioniq (AE): High Voltage Battery Control System / Battery Current Sensor. Specifications

Specification
Current (A)
Output Voltage (V)
-300 (Charge)
0.5
0
2.5
+300 (Discharge)
4.5

    DescriptionBattery Current Sensor is integrated into the Power Relay Assembly (PRA) and measures the current of the high voltage battery during charging or discharging.

    Circuit Diagram

    Other information:

    Hyundai Ioniq (AE) 2017-2022 Service & Repair Manual: Intake Actuator. Repair procedures

    Inspection1.Turn the ignition switch OFF.2.Disconnect the intake actuator connector.3.Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.Verify that the intake actuator operates to the recirculation position when connected in reverse.

    Hyundai Ioniq (AE) 2017-2022 Service & Repair Manual: General safety information and caution

    Safety PrecautionPrecautions To Take Before Servicing High Voltage System    â€¢ Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.