■ Hybrid vehicle

■ Plug-in hybrid vehicle
The high-voltage battery cooling duct is located on the left side of the rear seats.
The cooling duct cools down the high-voltage battery. When the highvoltage battery cooling duct is blocked, the high-voltage battery may be overheated and the vehicle performance may become limited and set a hybrid warning lamp. Do not obstruct the cooling duct with any other objects.
WARNING
Information
Clean the cooling duct for the hybrid battery with a dry cloth on a regular basis.
DANGER Never touch the safety plug.The safety plug is attached to high voltage hybrid battery system. Touching the safety plug will result in death or serious injury.
WARNING For your safety, do not touch high voltage cables, connectors and package modules. High voltage components are orange in color. Exposed cables or wires may be visible inside or outside of the vehicle.
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.
Diagnosis with GDS1.REAR CORENER RADAR system defects can be quickly diagnosed with the GDS. GDS operates actuator quickly to monitor, input/output value and self diagnosis.2.Connect the cable of GDS to the data link connector in driver side crash pad lower panel, turn the power on GDS.