| Specifications |
|
Classification
|
Unit
|
Specifications
| |
| Voltage | Vdc | 204 | |
| Driving | Torque | Nm / rpm / sec | 35.3 / 0 - 2160 / 5 |
| Output | kW / rpm / sec | 8.0 / 2160 - 12000 / 5 | |
| Generative | Torque | Nm / rpm / Min | 21.4 / 0 - 3250 / 20 |
| Output | kW / rpm / Min | 7.3 / 3250 - 15000 / 20 | |
| Maximum speed (mechanical limit) | rpm | 18000 | |
| Driving method | - | Belt - driven | |
| RPM (Base / Maximum) | rpm | 2160 / 15000 | |
Component location1. HPCU (Hybrid Power Control Unit)(LDC+MCU+HCU+Reservoir)2. Hybrid drive motor3. Hybrid starter generator (HSG)4. Electrical radiator5.
Removal • When working on the high voltage system, make sure that you are familiar and comply with the "Safety Precautions, Cautions and Warnings".
Inspection1.Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature.1. Ambient Sensor (+)2. Sensor groundSpecification Ambient temperature [°C (°F)] Resistance between terminal 1 and 2 (
Service Point Target Auto Calibration (SPTAC)When you need calibration :– Front view camera is removed and mounted– Replace front view camera with a new one – Windshield glass changed– Front view camera coupler of the windshield glass is deformedService Point T