Special Service Tools Tool (Number and name) Illustration Application Correction jig for LDWS or LKAS(09890-3V100)Correction of LDWS (Lane Departure Warning System) or LKAS (Lane keeping assist system).
Specifications Items Specifications Rated voltageDC 12VOperating temperature range-40 to +176°F (-40°C to +80°C)Rated loadWasherWasher : 5A (Motor load)
InspectionOperating Logic Test (Manual only)Inspect the PTC operation by confirmation logic as follows.1.Entering(1)Set the Floor mode and maximum heating position.(2)Turn off the blower switch.(3)Press the intake (recirculation) button 5 times or more.
Removal • Put on gloves to prevent hand injuries. • When removing with a flat-tip screwdriver or remover, wrap protective tape around the tools to prevent damage to components.