| Specification |
|
Item
|
Specification
|
| Input Voltage (V) | 200 - 310 |
| Output Voltage (V) | 12.8 - 14.7 |
| Rated Power (kW) | 1.8 |
| Cooling Method | Water-cooled |
DescriptionThe Low Voltage DC/DC is integrated into the HPCU. It charges the auxiliary battery as a substitute for generator by converting the high voltage (DC 270V) from the high voltage battery into low voltage (DC 12V).
Component Location1. Low Voltage DC/DC Converter (LDC)2. Power Outlet Terminal (DC 12V)3. Ground Terminal
Component Location1. Heater unit assemblyCompoents1. Heater core cover2. Heater core & Seal assembly3. Mode actuator [LH]4. Temperature control actuator [LH]5. Shower duct [LH]6. Duct sensor [Floor]7. PTC Heater8. Duct sensor [Vent]9. Heater & Evaporator lower case10.
DescriptionThe auto defogging sensor is installed on front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives a signal from the sensor and restrains moisture and eliminates defog by the intake actuator, A/C, auto defogging actuator, blower motor rpm and mod