| Component Location |

| 1. BCM (Body Control Module) | 2. Ultrasonic sensor |
|
Specification Item Specification Ultrasonic sensorVoltage ratingDC 12VDetecting range30 - 120cmOperation voltageDC 9 - 16VOperation currentMAX 350mAOperation temperature-30°C to +75°C (22°F to +167°F)Operation frequency48 ± 5KHzNumber of sensors8EA
System OverviewParking Distance Warning (PDW) is an electronic driving aid that warns the driver to be cautious while parking or driving at low speed.
Inspection1.Check that the voltage values of No. 1, 2 duct sensors change1. Sensor (+ 5V)2. Sensor groundSpecification Ambient temperature [°C (°F)] Resistance (kΩ) Voltage (V) 50 (122)1.
DescriptionIn ordinary cars, the mechanical water pump mounted on the engine for heating purposes is activated to circulate the cooling water, but in hybrid cars, AEWP is used to circulate the cooling water when the engine is not operating. Classification System Cooling water used