| Troubleshooting Flow |

Component Location1. BMS ECU2. Power Relay Assembly (PRA)3. Safety Plug4. Battery Temperature Sensor5. Battery Ambient Sensor • Main Relays (Positive, Negative), Pre-Charge Relay, Pre-Charge Resistor, and Battery Current Sensor are integrated into the PRA.
Schematic Diagram
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.