| Inspection |
| 1. | Connect the GDS on the Data Link Connector (DLC). |
| 2. | Turn the ignition switch ON. |
| 3. | Measure the output voltage of the APS 1 and 2 at C.T and W.O.T.
|
Circuit Diagram
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.
C