| Comoinents |

| 1. Air cleaner body 2. Air cleaner element 3. Air cleaner cover 4. Air flow sensor | 5. Air intake hose 6. Air duct hose 7. Air duct |
Removal and InstallationAir Cleaner Assembly1.Disconnect the battery negative terminal.2.Remove the air duct and air cleaner assembly. Tightening torque : Hose clamp : 2.
Inspection1.Turn the ignition switch OFF.2.Disconnect the mode control actuator connector.3.Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.Verify that the mode control actuator operates to the vent mode when connected in reverse.
Inspection1.Connect the battery voltage and check the blower motor rotation.2.If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.3.Replace the blower motor if it is proved that there is a problem with it.