| Specification |
|
Item
|
Specification
| |
| Contact | Rated Voltage (V) | 450 |
| Rated Current (A) | 20 | |
| Coil | Operating Voltage (V) | 12 |
| Resistance (Ω) | 40.0 - 110.0 [20°C (68°F)] | |
DescriptionThe Power Relay Assembly (PRA) consists of the positive and negative main relays, pre-charge relay, pre-charge resistor and battery current sensor.
Circuit Diagram
InspectionOperating Logic Test (Manual only)Inspect the PTC operation by confirmation logic as follows.1.Entering(1)Set the Floor mode and maximum heating position.(2)Turn off the blower switch.(3)Press the intake (recirculation) button 5 times or more.
DescriptionThe auto defogging sensor is installed on front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives a signal from the sensor and restrains moisture and eliminates defog by the intake actuator, A/C, auto defogging actuator, blower motor rpm and mod