| Description |
| • | Supplemental Restraint System Control Module (SRSCM) determines whether and when to deploy air bag module, seat belt pretensioner (BPT) and emergency fastenig device (EFD). |
| • | It supplies the air bag module with the power required to deploy the module or the BPT and EFD. |
| • | It also performs self-diagnosis function of the supplemental restraint system. |
Circuit Diagram
Components1. Supplemental Restraint System Control Module (SRSCM)Supplemental Restraint System Control Module (SRSCM) No Connector A Connector B 1IGN 1Ground2Driver front impact sensor - High (+)Driver seat belt pretensioner - High (+)3Driver front impact sensor - Low (-)Driver seat belt pretensioner - Low (-)4Driver airbag 1st stage - High (+)-5Driver airbag 1st stage - Low (-)-6Passenger airbag 1st stage - Low (-)Driver side airbag - High (+)7Passenger airbag 1st stage - High (+)Driver side airbag - Low (-)8Passenger airbag ON/OFF switch - Low (-)Passenger side airbag - Low (-)9Passenger airbag ON/OFF switch - High (+)Passenger side airbag - High (+)10Crash signal outputDriver side impact sensor - High (+)11Passenger front impact sensor - High (+)Driver side impact sensor - Low (-)12Passenger front impact sensor - Low (-)Passenger side impact sensor - Low (-)13-Passenger side impact sensor - High (+)14--15-Passenger seat belt pretensioner - High (+)16-Passenger seat belt pretensioner - Low (-)17P-CAN (High)-18P-CAN (Low)-19-Driver curtain airbag - High (+)20PAB OFF LampDriver curtain airbag - Low (-)21PAB ON LampPassenger curtain airbag - Low (-)22Driver Knee Airbag - High (+)Passenger curtain airbag - High (+)23Driver Knee Airbag - Low (-)Driver Passenger side impact sensor - High (+)24-Driver pressure side impact sensor - Low (-)25-Passenger pressure side impact sensor - Low (-)26C-CAN (High)Passenger Passenger side impact sensor - High (+)27C-CAN (Low)-28-29-30-31-32-33-34-35-36-37-38-39-
DescriptionThe In-car air temperature sensor is built in the heater & A/C control unit.The sensor contains a thermistor which measures the temperature of the inside. The signal decided by the resistance value which changes in accordance with perceived inside temperature, is delivered to heater control unit and according to this signal the contr
S