| Component |

| 1. Steering column 2. Multifunction switch | 3. Screw 4. Clock spring |


Specifications Items Specifications Rated voltageDC 12VOperating temperature range-40 to +176°F (-40°C to +80°C)Rated loadWasherWasher : 5A (Motor load)
Removal1.Disconnect the negative (-) battery terminal.2.Remove the steering wheel.(Refer to Steering System - "Steering Wheel")3.Remove the steering column upper and lower shrouds after loosening the screws.
DescriptionThe evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling. The evaporator temperature sensor has the Negative Temperature Coefficient (NTC).
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.