| Components |

| 1. EGR cooler pipe C 2. Electric EGR (EEGR) control valve 3. EGR cooler | 4. EGR cooler pipe A 5. Gasket 6. EGR cooler pipe B |
Removal and Installation1.Disconnect the battery negative terminal.2.Remove the air cleaner assembly.(Refer to Intake and Exhaust System - "Air Cleaner")3.
Description and Operation
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.
Inspection1.Turn the ignition switch OFF. 2.Disconnect the auto defogging connector. 3.Verify that the auto defogging actuator operates to the open position when connecting 12V to terminal 3 and grounding terminal 4. Verify that the auto defogging actuator operates to the close position when connected in reverse.