Inspection1.Turn the ignition switch OFF.2.Disconnect the OCV connector.3.Measure resistance between the OCV terminals 1 and 2.4.Check that the resistance is within the specification.
DescriptionFuel Pressure Control Valve is installed on the high pressure fuel pump and controls fuel flow flowing into the injectors in accordance with the ECM signal calculated based on various engine condition.
C
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.