| Specifications |
|
Classification
|
Unit
|
Specifications
| |
| Voltage | Vdc | 204 | |
| Driving | Torque | Nm / rpm / sec | 35.3 / 0 - 2160 / 5 |
| Output | kW / rpm / sec | 8.0 / 2160 - 12000 / 5 | |
| Generative | Torque | Nm / rpm / Min | 21.4 / 0 - 3250 / 20 |
| Output | kW / rpm / Min | 7.3 / 3250 - 15000 / 20 | |
| Maximum speed (mechanical limit) | rpm | 18000 | |
| Driving method | - | Belt - driven | |
| RPM (Base / Maximum) | rpm | 2160 / 15000 | |
Component location1. HPCU (Hybrid Power Control Unit)(LDC+MCU+HCU+Reservoir)2. Hybrid drive motor3. Hybrid starter generator (HSG)4. Electrical radiator5.
Removal • When working on the high voltage system, make sure that you are familiar and comply with the "Safety Precautions, Cautions and Warnings".
DescriptionThe auto defogging sensor is installed on the front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control module receives signal from the sensor and restrains moisture and eliminate defog by controlling the intake actuator, A/C, auto defogging actuator, blower moto
Inspection1.Turn the ignition switch OFF.2.Disconnect the mode control actuator connector.3.Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.Verify that the mode control actuator operates to the vent mode when connected in reverse.