Special Service Tools Tool (Number and name) Illustration Use Crankshaft damper pulley adapter(09231-2M100)Crankshaft damper pulley adapter holder(09231-2J210)Removal and installation of crankshaft damper pully bolt.
Removal and installation1.Remove the engine room under cover (A). Tightening torque : 3.9 - 5.9 N.m (0.4 - 0.6 kgf.m, 2.9 - 4.3 lb-ft)2.
DescriptionThe A/C Pressure Transducer (APT) converts the pressure value of high pressure line into voltage value after measuring it. By converted voltage value, engine ECU controls the cooling fan by operating it high speed or low speed. Engine ECU stops the operation of the compressor when the temperature of refrigerant line is very high or very
Inspection • Before measuring the pressure of the refriferant line, check whether the refrigerant amount is charged in accordance with the specified charging amount.(Refer to Heating, Ventilation, Air Conditioning - "Specifications")1.