| High Voltage Shut-off Procedures |
|
|
| 1. | Turn the ignition switch OFF and disconnect the auxiliary (-) battery negative (-) terminal. |
| 2. | Remove the safety plug cover (A).
|
| 3. | Unfasten the hook (A) and then remove the safety plug (C) by pulling the lever (B) to the direction of arrow.
|
| 4. | Wait for more than 5 minutes so that the capacitor in the high voltage system can be fully discharged. |
| 5. | Measure the voltage between the inverter terminals to check that the capacitor in the inverter is discharged completely.
|
Safety PrecautionPrecautions To Take Before Servicing High Voltage System • Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.
SpecificationsIgnition System Items Specification Ignition coilPrimary resistance0.56 Ω ± 10 %Spark plugsTypeELR9ISP8+Gap0.
Inspection1.Turn the ignition switch OFF.2.Disconnect the evaporator temperature sensor connector.3.Measure the resistance between terminal "+" and "-" of the evaporator temperature sensor.Specification Evaporator core temperature [°C (°F)] Resistance [KΩ]
Inspection1.Turn the ignition switch ON.2.Connect the GDS.3.Emit intensive light toward the photo sensor using a lamp, and check the output voltage change.4.The voltage will rise with higher intensive light and reduce with lower intensive light.1. Auto light signal2.