| Personal Protective Equipment |
|
Name
|
Illustration
|
Description
|
| Insulation glove |
| Used when inspecting or working on the high voltage components [Insulation performance : 1000V / 300A or above] |
| Insulation shoes |
| Used when inspecting or working on the high voltage components |
| Insulation clothes |
| |
| Insulation helmet |
| |
| Safety glasses |
| Used in the case below • During Removal & installation or inspection of the high voltage battery terminals or wiring, which spark might happen. • During working on the high voltage battery pack assembly. |
| Face shield |
| |
| Insulation mat |
| Putting the removed high voltage components on the insulation mat to prevent safety accidents. |
| Insulation sheet |
| Covering the high voltage components with insulation sheet to prevent people who don’t wear the personal protective equipment from safety accidents. |
SpecificationsHybrid Control SystemBrake Switchâ–· Type : ON/OFF Switchâ–· Specification Item Brake PedalRelease Brake PedalPush Switch 1Max.
Components1. Engine2. Hybrid Drive Motor3. HSG (Hybrid Starter Generator)4. Transaxle5. High Voltage Battery System6. Power Cable
Replacement When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage.1.Disconnect the negative (-) battery terminal.2.Recover the refrigerant with a recovery / recycling / charging station.
DescriptionThe temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch. Then the temperature will be regulated by the hot/cold air ratio decided by the position of the temper