| Components |

| 1. Air duct 2. Flap | 3. Housing 4. Actuator assembly |
Specifications Items Specifications Operating temperature -31 - 185°F (-35 - 85°C) Operating voltage DC 9 - 16V Rated voltage DC 12V Rated current (No load) 300mA or less [LH][RH]
Schematic DiagramCircuit Diagram
Inspection1.Turn the ignition switch OFF.2.Disconnect the temperature control actuator connector.3.Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.Verify that the temperature control actuator operates to the warm position when connected in reverse.
Inspection1.Turn the ignition switch OFF.2.Disconnect the intake actuator connector.3.Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.Verify that the intake actuator operates to the recirculation position when connected in reverse.