| Personal Protective Equipment |
|
Name
|
Illustration
|
Description
|
| Insulation glove |
| Used when inspecting or working on the high voltage components [Insulation performance : 1000V / 300A or above] |
| Insulation shoes |
| Used when inspecting or working on the high voltage components |
| Insulation clothes |
| |
| Insulation helmet |
| |
| Safety glasses |
| Used in the case below • During Removal & installation or inspection of the high voltage battery terminals or wiring, which spark might happen. • During working on the high voltage battery pack assembly. |
| Face shield |
| |
| Insulation mat |
| Putting the removed high voltage components on the insulation mat to prevent safety accidents. |
| Insulation sheet |
| Covering the high voltage components with insulation sheet to prevent people who don’t wear the personal protective equipment from safety accidents. |
SpecificationsHybrid Control SystemBrake Switchâ–· Type : ON/OFF Switchâ–· Specification Item Brake PedalRelease Brake PedalPush Switch 1Max.
Components1. Engine2. Hybrid Drive Motor3. HSG (Hybrid Starter Generator)4. Transaxle5. High Voltage Battery System6. Power Cable
Inspection1.Turn the ignition switch ON.2.Connect the GDS.3.Emit intensive light toward the photo sensor using a lamp, and check the output voltage change.4.The voltage will rise with higher intensive light and reduce with lower intensive light.1. Auto light signal2.
DescriptionThe mode control actuator is located at the heater unit.It adjusts the position of the mode door by operating the mode control actuator based on the signal of the A/C control unit. Pressing the mode select switch makes the mode control actuator shift in order of Vent → Bi-Level → Floor → Mix.