| Personal Protective Equipment |
|
Name
|
Illustration
|
Description
|
| Insulation glove |
| Used when inspecting or working on the high voltage components [Insulation performance : 1000V / 300A or above] |
| Insulation shoes |
| Used when inspecting or working on the high voltage components |
| Insulation clothes |
| |
| Insulation helmet |
| |
| Safety glasses |
| Used in the case below • During Removal & installation or inspection of the high voltage battery terminals or wiring, which spark might happen. • During working on the high voltage battery pack assembly. |
| Face shield |
| |
| Insulation mat |
| Putting the removed high voltage components on the insulation mat to prevent safety accidents. |
| Insulation sheet |
| Covering the high voltage components with insulation sheet to prevent people who don’t wear the personal protective equipment from safety accidents. |
SpecificationsHybrid Control SystemBrake Switchâ–· Type : ON/OFF Switchâ–· Specification Item Brake PedalRelease Brake PedalPush Switch 1Max.
Components1. Engine2. Hybrid Drive Motor3. HSG (Hybrid Starter Generator)4. Transaxle5. High Voltage Battery System6. Power Cable
DescriptionThe In-car air temperature sensor is built in the heater & A/C control unit.The sensor contains a thermistor which measures the temperature of the inside. The signal decided by the resistance value which changes in accordance with perceived inside temperature, is delivered to heater control unit and according to this signal the contr