Inspection1.Check the temperature sensor resistance. [Hybrid drive motor] Measuring equipment : Multimeter Category Inspection area Inspection criteria Remarks Resistance(Temperature sensor)Pin 4 - 88kΩ (30°C / 86°F) - 20kΩ (10°C / 50°F)10 - 30°C / 50 - 86°F [Hybrid starter generator (HSG)] Measuring equipment : Multimeter Category Inspection area Inspection criteria Remarks Resistance(Temperature sensor)Pin 4 - 9126.
Description• Various devices containing semiconductor are used in HPCU.And heat is generated when the HPCU operates.• These devices are connected to the high voltage directly and cause heat hotter than the electrical devices of an internal combustion engine.
Replacement When prying with a flat-tip screwdriver or use a prying trim tool, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage.1.Disconnect the negative (-) battery terminal.2.Recover the refrigerant with a recovery / recycling / charging station.
DescriptionThe temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch. Then the temperature will be regulated by the hot/cold air ratio decided by the position of the temper