Inspection1.Check the temperature sensor resistance. [Hybrid drive motor] Measuring equipment : Multimeter Category Inspection area Inspection criteria Remarks Resistance(Temperature sensor)Pin 4 - 88kΩ (30°C / 86°F) - 20kΩ (10°C / 50°F)10 - 30°C / 50 - 86°F [Hybrid starter generator (HSG)] Measuring equipment : Multimeter Category Inspection area Inspection criteria Remarks Resistance(Temperature sensor)Pin 4 - 9126.
Description• Various devices containing semiconductor are used in HPCU.And heat is generated when the HPCU operates.• These devices are connected to the high voltage directly and cause heat hotter than the electrical devices of an internal combustion engine.
C
InspectionOperating Logic Test (Manual only)Inspect the PTC operation by confirmation logic as follows.1.Entering(1)Set the Floor mode and maximum heating position.(2)Turn off the blower switch.(3)Press the intake (recirculation) button 5 times or more.